Air Conditioner Guide

SEER2 Explained: 2026 Minimums, SEER Conversion and Payback

SEER vs SEER2: the 2023 test change, a conversion table, 2026 regional minimums, ENERGY STAR status and payback for 16 to 22 SEER2 in six states.

By Air Conditioner Guide Editorial TeamPublished July 10, 2026Updated November 10, 2026Reviewed by Air Conditioner Guide Editorial Team
Rows of residential-style electricity meters mounted on a utility panel
Efficiency ratings estimate seasonal output per unit of electricity under test conditions.Photo on Unsplash

The short answer

SEER2 is the seasonal cooling efficiency rating required since January 1, 2023, measured under DOE's Appendix M1 test at 0.5 inches of external static pressure, so a ducted split system rates about 5 percent lower than on the old SEER scale (14 SEER became 13.4 SEER2). A new split AC must reach 13.4 SEER2 in the North and 14.3 SEER2 in the Southeast and Southwest. On 2026 EIA rates, moving a 3-ton system from 14.3 to 16 SEER2 saves about $146 a year in Texas and $88 in Illinois.

SEER2 is the cooling efficiency rating on every central air conditioner and heat pump made for the US market since January 1, 2023: the heat a system removes over a modeled cooling season, divided by the electricity it uses, measured under DOE's Appendix M1 test. That test pushes air against 0.5 inches of water column of external static pressure instead of the old 0.1 to 0.2, so a ducted split system rates about 5 percent lower than it did on the SEER scale, and the old 14 SEER became 13.4 SEER2. The federal floor for a new split AC is 13.4 SEER2 in the North and 14.3 SEER2 in the Southeast and Southwest, where the Southwest adds an EER2 minimum. Whether paying for more pays off depends on your cooling hours and electricity rate, worked out below for six states.

Quick answer

QuestionShort answerBasis
What is SEER2?Seasonal cooling output per watt-hour, tested under DOE Appendix M1 since January 1, 2023DOE, 10 CFR 430.32
How is it different from SEER?Ducted units are tested at 0.5 in. w.c. of static pressure, not 0.1 to 0.2, so numbers come out lowerAppendix M1
How much lower?About 5% for ducted split systems; DOE's own translations run 4.3% to 5.0%AHRI factor, DOE 2017 rule
Minimum for a new split AC13.4 SEER2 North; 14.3 Southeast and Southwest (13.8 at 45,000 Btu/h and up)DOE, 2023 standards
Southwest extra11.7 EER2 (11.2 at 45,000 Btu/h and up), or 9.8 EER2 at 15.2 SEER2 and higherDOE
ENERGY STARCentral AC label ended February 1, 2026; heat pumps still certify at 15.2 SEER2EPA
Worth paying more?Usually up to 17 or 18 SEER2 in the hot-humid South and in high-rate states; rarely in Arizona on DOE's hoursOur arithmetic below

What SEER2, EER2 and HSPF2 measure

SEER2 divides the heat a system removes over a modeled cooling season by the electricity it uses, in Btu per watt-hour. Part-load hours count, so two-stage and variable-speed equipment can score far higher. EER2 is the full-load figure at 95°F outdoors; DOE's 2022 FAQ says it matters most in hot-dry climates, which is why only the Southwest has an EER2 floor. HSPF2 is the heat pump heating-season figure; heating-first questions belong on our sister site's heat pump vs gas furnace guide. All three belong to a certified indoor and outdoor pair, not to the outdoor cabinet alone.

SEER vs SEER2: what changed in the test

The equipment did not get worse in 2023; the test got harder. DOE's 2017 rule says ratings can differ "despite no changes to design." What moved, per New York State Clean Heat's summary of Appendix M1:

Test conditionOld SEER, Appendix MSEER2, Appendix M1
Static pressure, ducted units0.1 to 0.2 in. w.c.0.5 in. w.c.
Default fan power, coil-only rating365 W per 1,000 cfm441 W per 1,000 cfm
Heating test temperatures47°F and 17°F47°F, 17°F and 5°F
Heating load line starts at65°F55°F
Required for units madeBefore January 1, 2023On or after January 1, 2023

External static pressure is the resistance the blower pushes against from ducts, filter and coil. DOE changed the test so ratings "better reflect real-world installation and use," and the higher pressure charges ducted systems for more blower work. New York's January 2024 fact sheet says ductless ratings came out "the same or slightly lower," while ducted ratings were "more impacted due to greater external static pressure sensitivity." DOE also warns that the new metrics "are not directly comparable" with the old ones, and New York says "Each heat pump responds differently." Any conversion is an average, not a promise about one model.

SEER to SEER2 conversion table

Two published methods agree within 0.1 point.

  1. AHRI's conversion factors, adopted by RESNET in Addendum 71i on December 4, 2022: SEER2 equals SEER times 0.95 for ducted split and packaged systems and times 1.00 for ductless. EER2 uses the same 0.95 for ducted systems. HSPF2 equals HSPF times 0.85 for ducted split systems and 0.90 for ductless.
  2. DOE's translation of its own standards in its January 2017 direct final rule, which published the 2023 minimums on both tests side by side. Those pairs are the only official equivalents, and they put SEER2 4.3% to 5.0% below SEER for split air conditioners.
Old ratingSEER2 at AHRI's 0.95DOE's translationWhat it means in 2026
13 SEERabout 12.4None publishedThe 2015 to 2022 North floor; below today's 13.4 minimum
14 SEER13.313.4Today's North floor for a split AC
15 SEERabout 14.314.3Southeast and Southwest floor; heat pump floor everywhere
16 SEER15.215.2Southwest EER2 break point; ENERGY STAR heat pump level
18 SEER17.1None publishedTop of most two-stage lines, 17.2 to 18 SEER2
20 SEER19.0None publishedVariable-speed equipment only

To go the other way, divide by 0.95: 16 SEER2 is roughly 16.8 SEER. This matters when you compare a quote with the sticker on your old unit. A 13 SEER system would rate about 12.4 SEER2 on today's test, so a 15.2 SEER2 replacement uses about 19 percent less electricity per unit of cooling on paper, and a 17 SEER2 replacement about 27 percent less.

The peak and heating metrics moved by different amounts:

RequirementOld standardSEER2-era standardDrop
Southwest split AC, under 45,000 Btu/h12.2 EER11.7 EER24.1%
Southwest split AC, 45,000 Btu/h and up11.7 EER11.2 EER24.3%
Southwest split AC at 16 SEER or 15.2 SEER2 and up10.2 EER9.8 EER23.9%
Split heat pump heating8.8 HSPF7.5 HSPF214.8%
Single-package heat pump heating8.0 HSPF6.7 HSPF216.3%

HSPF2 fell about three times as far as SEER2, largely because Appendix M1 also changed the heating load line. DOE describes a "15% reduction from HSPF to HSPF2," so never compare the two directly.

What SEER2 rating do I need? Federal minimums for 2026

These standards, from 10 CFR 430.32(c) and DOE's 2022 FAQ, have applied since January 1, 2023 and were unchanged when we checked on October 16, 2026.

EquipmentNorthSoutheastSouthwest
Split AC, under 45,000 Btu/h13.4 SEER214.3 SEER214.3 SEER2 and 11.7 EER2
Split AC, 45,000 Btu/h and up13.4 SEER213.8 SEER213.8 SEER2 and 11.2 EER2
Single-package AC13.4 SEER213.4 SEER213.4 SEER2 and 10.6 EER2
Split heat pump14.3 SEER2, 7.5 HSPF2SameSame
Single-package heat pump13.4 SEER2, 6.7 HSPF2SameSame
Rule applies byDate of manufactureDate of installationDate of installation

In the Southwest, a split AC certified at 15.2 SEER2 or higher needs only 9.8 EER2. Heat pumps meet one national standard. The 45,000 Btu/h line uses certified capacity, not nominal size: one 3-ton outdoor unit we examined certifies at 33,000 to 35,200 Btu/h, 92% to 98% of nominal, so a nominal 4-ton (48,000 Btu/h) at 92% would certify near 44,200 and fall under the stricter column.

Which region is your state in?

  • Southeast: Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, South Carolina, Tennessee, Texas, Virginia, the District of Columbia, Puerto Rico and the US territories.
  • Southwest: Arizona, California, Nevada and New Mexico.
  • North: the other 30 states: Alaska, Colorado, Connecticut, Idaho, Illinois, Indiana, Iowa, Kansas, Maine, Massachusetts, Michigan, Minnesota, Missouri, Montana, Nebraska, New Hampshire, New Jersey, New York, North Dakota, Ohio, Oregon, Pennsylvania, Rhode Island, South Dakota, Utah, Vermont, Washington, West Virginia, Wisconsin and Wyoming.

DOE drew the North/South line at 5,000 population-weighted heating degree days.

Date of manufacture vs date of installation

  • North: date of manufacture. A split AC built before January 1, 2023 that met the old 13 SEER standard can still be installed in the North until that inventory runs out (10 CFR 430.32(c)(5)). Anything built later must meet 13.4 SEER2.
  • Southeast and Southwest: date of installation. Since January 1, 2023, only models that meet the regional SEER2 and EER2 standards may be installed there (10 CFR 430.32(c)(6)). DOE defines installation as "the connection of the refrigerant lines and/or electrical systems to make the central air conditioner operational." Purchase and delivery dates do not count.
  • The coil-only rule. For single-stage and two-stage split ACs, every certified combination of an outdoor model, including a least-efficient coil-only match, must meet the regional standard, so one weak combination makes the outdoor model North-only. Leftover stock can go into the South only if it was previously validly certified to the regional standard (10 CFR 429.102(c)(4)(i)).

MRCOOL's 28 AHRI certificates for its 3-ton outdoor unit HAC13036FA, dated December 12, 2024, show it: five reach 14.30 SEER2 and 11.70 EER2, yet all 28 list the region as North only, because the other 23 certify at 13.40 SEER2. DOE's 2022 FAQ takes reports of illegal installs at EnergyEfficiencyEnforcement@doe.gov.

What to target by situation

Using the payback results below:

Your situationSensible SEER2 targetWhy
North, power under about 20 cents/kWh13.4 to 16In our Illinois example, 14.3 to 16 SEER2 saves $88 a year
North, power near 30 cents/kWh16 to 18New York's rate makes 17 to 18 SEER2 pay back in 5 to 15 years
Hot-humid South16 to 1817 and 18 SEER2 pay back in 4 to 14 years at better-tier prices
Hot-dry Southwest14.3 to 16, with EER2 checkedAt DOE's 1,599 hours, upgrades save $66 to $218 a year
Humidity or noise problemsTwo-stage or variable-speedComfort, not SEER2, is the reason to buy
Heating system also duePrice a heat pump, 14.3 SEER2 minimumOne machine replaces two

See our central AC vs heat pump comparison for the last row and the compressor-type guide for the comfort row.

ENERGY STAR in 2026: central ACs out, heat pumps in

EPA ended the ENERGY STAR specification for central air conditioners on February 1, 2026, as finalized in its December 2, 2024 letter. No new certifications were accepted after July 15, 2025, and the mark must come off central ACs made from February 1, 2026, though old packaging may be used up, so a box with the logo can still turn up. Heat pumps still certify:

ProductENERGY STAR status, October 2026Minimum to certify
Central AC, split or packagedSpecification ended February 1, 2026None
Split air-source heat pumpCertifies15.2 SEER2, 11.0 EER2, 7.8 HSPF2
Single-package heat pumpCertifies15.2 SEER2, 10.0 EER2, 7.2 HSPF2
Cold climate, ducted splitCertifies15.2 SEER2, 8.1 HSPF2, COP 1.75 at 5°F
Cold climate, ductlessCertifies15.2 SEER2, 8.5 HSPF2, COP 1.75 at 5°F

Cold climate models must also keep at least 70% of their 47°F heating capacity at 5°F. FEMP's December 2024 guidance still cites 15.2 SEER2 as the ENERGY STAR central AC level. A rebate that requires an "ENERGY STAR central air conditioner" can no longer be met by new equipment, so look for the program's SEER2 threshold.

Is a higher SEER2 worth it? The payback math

The formula

Annual cooling kWh = capacity in Btu/h × full-load cooling hours ÷ (SEER2 × 1,000)

Our sizing and cost calculator runs this formula, and so does DOE's FEMP: its hot-humid example for a 15.2 SEER2 system lands on 8,074 kWh a year, exactly what the formula gives. The inputs:

  • Capacity: 36,000 Btu/h, a 3-ton system and FEMP's reference size. A 2-ton saves two-thirds of each figure and a 4-ton a third more.
  • Cooling hours: FEMP's equivalent full-load hours: 3,409 in the hot-humid Southeast, 1,599 in the hot-dry Southwest and 1,705 in the North.
  • Electricity: EIA's average residential price for January through July 2026 (Electric Power Monthly, Table 5.6.B, released September 24, 2026): Texas 16.06, Florida 15.30, Georgia 15.40, Arizona 15.44, Illinois 19.22 and New York 29.38 cents per kWh.
  • Baseline: 14.3 SEER2, the Southeast and Southwest floor and our calculator's base case.
  • Price premium: our cost model, data version 2026-07-10, as published in the 3-ton installed cost guide: better tier adds $1,200 to $3,000 over standard, premium adds $3,500 to $7,000. We price 16, 17 and 18 SEER2 as better tier and 20 and 22 as premium. In lineups we checked in July and August 2026, single-stage lines top out at 16.5 to 17.0 SEER2 (Carrier Comfort, Goodman GLXS, Lennox EL16KC1), two-stage and multi-speed at 17.2 to 18 (Goodman GLXT7C, Bryant Preferred 148TAN, Trane 17 Multi-Speed), and every line above 18 is variable-speed (Goodman GXV9S at 19, Rheem RA19AY at 20, Carrier Infinity at 21.0, Lennox EL22KCV at 22.5).
  • Left out: rebates, future rate changes, financing and discounting.

Worked example: Texas, 14.3 vs 16 SEER2

36,000 Btu/h × 3,409 hours is 122,724,000 Btu of cooling a year. Divided by 14,300, a 14.3 SEER2 system uses 8,582 kWh. Divided by 16,000, a 16 SEER2 system uses 7,670 kWh. The 912 kWh difference at 16.06 cents is $146 a year. A $1,200 premium pays back in 8.2 years, a $3,000 premium in 20.5.

Annual cooling electricity, 3-ton system

SEER2Hot-humid, 3,409 hHot-dry, 1,599 hNorth, 1,705 h
13.49,159 kWh4,296 kWh4,581 kWh
14.38,582 kWh4,025 kWh4,292 kWh
15.28,074 kWh3,787 kWh4,038 kWh
167,670 kWh3,598 kWh3,836 kWh
177,219 kWh3,386 kWh3,611 kWh
186,818 kWh3,198 kWh3,410 kWh
206,136 kWh2,878 kWh3,069 kWh
225,578 kWh2,617 kWh2,790 kWh

Yearly savings vs 14.3 SEER2

Better tier, $1,200 to $3,000 extra:

State16 SEER217 SEER218 SEER2
Texas$146$219$283
Florida$140$209$270
Georgia$140$210$272
Arizona$66$99$128
Illinois$88$131$170
New York$134$200$259

Premium tier, $3,500 to $7,000 extra:

StateCooling cost at 14.320 SEER222 SEER2
Texas$1,378$393$482
Florida$1,313$374$460
Georgia$1,322$377$463
Arizona$622$177$218
Illinois$825$235$289
New York$1,261$359$441

Years to pay back the premium

Better tier, years at $1,200 to $3,000:

State16 SEER217 SEER218 SEER2
Texas8 to 205 to 144 to 11
Florida9 to 226 to 144 to 11
Georgia9 to 216 to 144 to 11
Arizona18 to 4512 to 309 to 23
Illinois14 to 349 to 237 to 18
New York9 to 226 to 155 to 12

Premium tier, years at $3,500 to $7,000:

State20 SEER222 SEER2
Texas9 to 187 to 15
Florida9 to 198 to 15
Georgia9 to 198 to 15
Arizona20 to 4016 to 32
Illinois15 to 3012 to 24
New York10 to 198 to 16

What each upgrade is worth over 15 years

We plan around a 15-year service life for a central AC. Yearly saving times 15 is the most an upgrade can cost and still pay for itself in electricity, whatever tier the contractor calls it:

State16 SEER218 SEER220 SEER222 SEER2
Texas$2,197$4,250$5,892$7,236
Florida$2,093$4,049$5,613$6,894
Georgia$2,106$4,075$5,650$6,939
Arizona$991$1,916$2,657$3,263
Illinois$1,315$2,544$3,527$4,331
New York$2,010$3,888$5,391$6,621

Reading the results

  • Hot-humid South: 17 and 18 SEER2 pay back in 4 to 14 years across the whole better-tier band. A 16 SEER2 upgrade needs a premium under about $2,100 to $2,200.
  • New York behaves like Texas: half the hours at nearly twice the rate puts its savings within about 10% of the Texas figures.
  • Arizona, on DOE's 1,599 hours: only 17 and 18 SEER2 at a $1,200 premium pay back inside 15 years, at 12.2 and 9.4 years.
  • Illinois: 18 SEER2 at $1,200 pays back in about 7 years; 16 SEER2 only makes sense under about $1,315.
  • Premium tier: in Texas, Florida, Georgia and New York, 20 SEER2 pays back inside 15 years only under about $5,400 to $5,900 extra, and 22 SEER2 under about $6,600 to $7,200. In Arizona and Illinois they take 12 to 40 years; buy them there for humidity control and quiet.
  • Why 18 SEER2 looks best: our model prices tiers, not individual ratings, so 16, 17 and 18 carry the same add. If your quote prices an 18 SEER2 system like a premium unit, use the 15-year table instead.

The North's lower floor

In the North, 13.4 SEER2 is legal. Measured from 13.4, 16 SEER2 saves $143 a year in Illinois and $219 in New York, and 18 SEER2 saves $225 and $344. Even 13.4 to 14.3 is worth $55 and $85.

What the payback math leaves out

  • Rates move. EIA's US average residential price for January through July 2026 is 18.19 cents, up from 17.01 a year earlier. Each 10% rate increase cuts every payback period by about 9%.
  • Duct losses scale the savings. A 20% duct loss raises both bills by the same proportion and makes every saving 25% larger, but sealing the ducts is usually cheaper; our mini-split vs central air guide runs those numbers.
  • Comfort and complexity. Carrier lists its single-stage Comfort series as low as 71 dBA and variable-speed Infinity as low as 55 dBA. Higher tiers often need a specific control, which our cost model prices at $500 to $2,000.

Rebates can change the math

Utility rebates mostly key off certified SEER2 tiers or ENERGY STAR heat pump status, and vary by utility. Two programs we verified on October 16, 2026:

CPS Energy, San Antonio, Texas. Rebates per cooling ton for a central AC, heat pump or ductless system, for projects completed between February 1, 2026 and January 31, 2027:

TierCertified SEER2Replace on burnoutEarly replacement3-ton, burnout
113.8 to 15.1$90 per ton$115 per ton$270
215.2 to 16.1$120 per ton$130 per ton$360
316.2 to 17.0$150 per ton$175 per ton$450
417.1 to 19.9$225 per ton$250 per ton$675
520.0 and up$275 per ton$310 per ton$825

CPS verifies ratings from the AHRI certificate, requires a Texas-licensed contractor, a one-for-one replacement and an application within 30 days, and caps the rebate at project cost. Early replacement needs working equipment under 25 years old. CPS pays first come, first served and can change or end the rebate without notice, so confirm funding before you count on it.

In the Texas example at burnout rates, an 18 SEER2 system earns $405 more than a 14.3 SEER2 one on a 3-ton job, cutting its payback from 4.2 to 10.6 years to 2.8 to 9.2. A 16 SEER2 system gains only $90 because it sits in tier 2. Tier edges matter: a 16.2 SEER2 match earns $90 more than a 16.1 match, so ask for the certified number of every indoor match the contractor could use. CPS rates differ from the Texas average, so rerun it with your bill.

Otter Tail Power, Upper Midwest. $100 per unit for an air conditioner with an ENERGY STAR rating or 15.2 SEER2 or higher, plus $50 when a contractor in its quality installation program does the work, $150 in total on its 2026 form. With ENERGY STAR out of central ACs, 15.2 SEER2 is the path a new system can use.

Elsewhere, search the ENERGY STAR Rebate Finder by ZIP code and read the SEER2 tier, not the headline amount. CPS pays the same per ton for a heat pump as for an AC, so price both. The federal 25C credit does not apply to property placed in service after December 31, 2025, per the IRS; our 2026 central AC tax credit page tracks it.

Why the SEER2 label differs from your bill

SEER2 is a laboratory number for a certified pair under fixed conditions. Your house changes most of them.

FactorWhat happens in a real houseWhat to ask for
Indoor matchOne outdoor unit can carry many ratings; MRCOOL's 3-ton spans 13.40 to 14.30 SEER2The AHRI certificate for your exact pair
Static pressureTight returns and dense filters push airflow off the rated pointMeasured static pressure and airflow at startup
Duct leakageENERGY STAR: about 20 to 30% of air lost in a typical duct systemA duct leakage test or a sealing price
Charge and airflow faultsNIST: a 30% rise in energy use from poor installation is plausibleCharge method and readings in writing
OversizingShort cycles, weak dehumidification, lower set pointsA room-by-room Manual J load

ENERGY STAR's quality installation checklist names four basics: equipment sized to the home, airflow to the manufacturer's specification, a tested refrigerant charge, and ducts inspected, leak-tested and repaired. NIST's 2014 study of installation faults (Technical Note 1848) found duct leakage, undercharge, oversizing on ordinary ducts, low airflow and overcharge had the most potential to raise energy use, with leakage plus undercharge "well-beyond additive." In its Houston simulation, lowering the thermostat 2°F to offset fault-driven humidity raised annual energy use by 20%.

Sizing is the fault a quote controls directly: an oversized single-stage unit short cycles and leaves the house clammy. See our sizing guide and short cycling guide. On DOE's hot-humid hours, a 20 SEER2 system losing 30% to its ducts uses 8,766 kWh, more than a 15.2 SEER2 system on tight ducts at 8,074.

How to check the SEER2 on a quote

The brochure number is a ceiling. The AHRI certificate is what you are buying.

  1. Get every model number: outdoor unit, indoor coil or air handler, the furnace if its blower is in the match, and the AHRI Certified Reference Number.
  2. Search the AHRI Directory at ahridirectory.org with the AHRI Reference # option. With model numbers only, AHRI advises entering fewer characters than the nameplate shows.
  3. Download the certificate by clicking the reference number in the record.
  4. Check five lines: models match the quote; AHRI type (RCU-A-CB is coil with blower, RCU-A-C coil only); the region includes your state; SEER2 and EER2 clear your floor; cooling capacity at 95°F.
  5. Match it to the money: the certified SEER2 belongs in the contract, any savings claim and any rebate form.

"Up to" is not your rating. Carrier's 2026 comparison lists Comfort, Performance and Infinity at up to 16.5, 18.0 and 21.0 SEER2; Trane lists its 20 TruComfort at up to 23.6 and Lennox its SL25KCV at up to 26.0. Those are the best pairings in each family. With your indoor unit the certificate can come back lower; MRCOOL's spans nearly a full point on one outdoor unit.

Quote red flags:

  • A SEER2 number with no AHRI reference, or no indoor model.
  • "16 SEER" on a 2026 quote, the old metric.
  • A savings claim without your rate, both SEER2 ratings and the hours assumed.
  • A Southwest quote with no EER2.
  • A North-only certificate for a house in the Southeast or Southwest.
  • An upgrade sold on a federal tax credit for a 2026 install.

Our quote comparison worksheet puts the AHRI check beside its 16-line scope check, or send your proposal for an independent read.

FAQ

Is 16 SEER the same as 16 SEER2?

No. A 16 SEER system on the old test rates about 15.2 SEER2 on the current one, using AHRI's 0.95 factor for ducted split systems, and DOE used the same 16 to 15.2 pairing for the Southwest EER threshold. 16 SEER2 is roughly 16.8 SEER. The equipment is the same; the 2023 test adds duct resistance.

What SEER2 rating do I need in 2026?

A new split AC needs 13.4 SEER2 in the North and 14.3 SEER2 in the Southeast and Southwest under 45,000 Btu/h, or 13.8 SEER2 at 45,000 Btu/h and up. The Southwest also requires 11.7 or 11.2 EER2, or 9.8 EER2 from 15.2 SEER2. Split heat pumps need 14.3 SEER2 and 7.5 HSPF2 everywhere. Above the floor, 16 to 18 SEER2 is where hot-climate and high-rate buyers usually get their money back.

Is a higher SEER2 worth the extra cost?

It depends on hours and rates more than the rating. On a 3-ton system at 2026 EIA rates, 14.3 to 18 SEER2 saves $283 a year in Texas, $259 in New York, $170 in Illinois and $128 in Arizona; at a $1,200 to $3,000 premium that pays back in 4 to 11 years in Texas and 9 to 23 in Arizona. 20 and 22 SEER2 pay back within 15 years only in hot-humid or high-rate states, and only below roughly $5,400 to $7,200 extra.

Can a contractor still install an old 14 SEER air conditioner?

In the North, yes, if it was manufactured before January 1, 2023 and met the standard in force then, because the North rule follows date of manufacture. In the Southeast and Southwest, no: a split AC installed there since that date must be certified to the regional SEER2 standard, and an old 14 SEER unit works out to about 13.3 SEER2, below the 14.3 floor.

Does ENERGY STAR still certify central air conditioners?

No. EPA ended the central AC specification on February 1, 2026, stopped accepting new certifications on July 15, 2025, and requires manufacturers to drop the mark on units made from February 1, 2026. Air-source heat pumps still certify at 15.2 SEER2, 11.0 EER2 and 7.8 HSPF2 for split systems.

Do ductless mini-splits lose points under SEER2 too?

Barely. AHRI's conversion factor for ductless systems is 1.00, and New York's Clean Heat program says ductless ratings came out the same or slightly lower under the new test, while ducted ratings dropped more. Our mini-split vs central air guide compares their running costs.

What we could not verify

  • DOE's hot-dry cooling hours. FEMP's 1,599 full-load hours for the Southwest are lower than its 1,705 for the North, and FEMP does not explain why. We kept them so our numbers match our calculator, but they look low for desert cities, and more hours would shorten every Arizona payback.
  • A universal SEER-to-SEER2 factor. DOE says the metrics are "not directly comparable" and New York says each product responds differently. The 0.95 factor is AHRI's modeling average; DOE's translations range from 4.3% to 5.0%. Your old unit's SEER2 was never measured.
  • Field static pressure. We found no current primary source for how far installed systems typically run above the 0.5 in. w.c. test condition.
  • A price premium for each SEER2 number. Our cost model prices three tiers, not individual ratings, and no federal agency publishes installed prices by SEER2. HomeGuide, Angi and HomeAdvisor block automated checks, so we did not use their figures.
  • Rebates beyond the two programs above. We saw third-party reports of 2026 AC rebates from Salt River Project and Tucson Electric Power and of APS ending residential rebates, but could not confirm them on the utilities' own pages.
  • How ratings hold up over time. We found no primary source on how delivered efficiency changes over 15 years, so the payback math assumes the rated SEER2 holds.

Sources

All sources checked October 16, 2026 unless noted.

How this guide is checked

Written by Air Conditioner Guide Editorial Team. Editorial review by Air Conditioner Guide Editorial Team, last reviewed October 16, 2026. We check the sizing logic, quote-scope claims, and sources. No affiliate ranking bias.

Have a proposal?

Check the quote before you sign.

We'll look at the model match, capacity basis, install scope, warranty, and missing questions. Free, independent, no lead auction.

Check my quote